Heat Pumps
Carrier Base 15 Heat Pump with Puron® Refrigerant, Model 25HBB5, is available in 1.5-5 ton nominal-sized units.
STANDARD FEATURES
Energy Efficiency
- 15 SEER / 12.5 EER / 8.5 – 8.8 HSPF
Aesthetic Design
- WeatherArmor™ System
- Baked-on powder paint
Quiet Operation
- Sound as low as 71 dBA
Reliability, Quality and Durability
- Scroll Compressor
- Field-installed Filter Drier
- Front-seating Service Valves
- High-Pressure Switch
- Loss-of-Charge Switch
- Internal Pressure-Relief Valve
- Internal thermal overload
- Suction Line Accumulator
- Dense wire coil guard available (“A” model)
- Standard wire coil guard available (“W” model)
Carrier Comfort™ 15 Heat Pump with Puron® Refrigerant, Model 25HCB5, is available in 1.5-5 ton nominal-sized units.
Standard Features
Energy Efficiency
- 14.5 – 15 SEER / 11.7 – 13 EER / 7.7-9.0 HSPF
New Aesthetic Design
- WeatherArmor™ System
- Baked-on powder paint
- Steel-louver Coil Guard
Quiet Operation
- Sound as low as 70 dBA
Reliability, Quality and Durability
- Scroll Compressor
- Field-installed Filter Drier
- Front-seating Service Valves
- High-Pressure Switch
- Loss-of-Charge Switch
- Internal Pressure-Relief Valve
- Internal thermal overload
The Carrier Performance 15 Series Heat Pump, with Puron refrigerant, Model 25HPA5, is available in 1.5 – 5 ton nominal sized units.
Standard Features
Energy Efficiency
- 15 SEER/12 EER/8.5 HSPF
New Aesthetic Design
- WeatherArmor UltraTM
– Baked on powder paint
– Steel louver coil guard
– Color matched cabinet screws
Extra Quiet Operation
- Silencer System IITM for sound as low as 68 dBA
– Quiet mount split post compressor grommets
– External silencer muffler
– Exclusive Silencer Top design
– 8 Pole PSC ball bearing condenser fan motor
– Forward-swept condenser fan blade
– Compressor blanket
- Quiet Shift Defrost
Reliability, Quality and Toughness - Scroll compressor
- Field-installed 16 cu. in. filter drier
- Back-seating service valves
- High pressure switch
- Loss of charge switch
- Internal pressure relief valve
- Internal thermal overload
- Suction line accumulators
- Vapor Fog Eliminator Controls and Diagnostics
- InfinityTM control compatible
- Utility Interface Connection
- Up to 14 point diagnostic capability
- Long line accessory connections
- Ideal Defrost
Applications - Long-line – up to 250 ft. total equivalent length, see Long Line Guide for more information
- Low ambient (down to 0oF)
Carrier Performance™ 16 2-Stage Heat Pump with Puron® Refrigerant, Model 25HPA6, is available in 2-5 ton nominal-sized units.
STANDARD FEATURES
Energy Efficiency
- 15.5 – 16.5 SEER / 12.5 / 9.0 – 9.5 HSPF
(based on tested combinations)
Aesthetic Design
- WeatherArmor™ System
- Baked-on powder paint
- Steel-louver Coil Guard
Quiet Operation
- Sound as low as 69 dBA
Reliability, Quality and Durability
- 2-Stage Scroll Compressor
- Field-installed Filter Drier
- Front-seating Service Valves
- High-Pressure Switch
- Loss-of-Charge Switch
- Internal Pressure-Relief Valve
- Internal thermal overload
- Suction Line Accumulator
- Crankcase Heater – Standard
Application/Serviceability
- Infinity™ or thermostat control
- Utility interface connections
- Enhanced diagnostics with Infinity Control
- Low Ambient cooling to 0°F with complete Infinity™ System
The Carrier Infinity 16 Series Two-Stage Heat Pump, with Puron refrigerant, Model 25HNA6, is available in 2-5 ton nominal sized units.
Standard Features
Energy Efficiency
- 15-16 SEER/10.6-12.0 EER/8.4-9.0 HSPF
New Aesthetic Design
- WeatherArmor UltraTM
– Baked on powder paint
– Steel louver coil guard
– Color matched cabinet screws
Extra Quiet Operation
- Silencer System IITM for sound as low as 74 dBA
– Quiet mount split post compressor grommets
– Quiet External silencer muffler
– Exclusive Silencer Top design
– 8 Pole PSC
– Forward-swept condenser fan blade
– Compressor blanket
- Quiet Shift Defrost
Reliability, Quality and Toughness - Two-Stage reciprocating compressor
- Field-installed 16 cu. in. filter drier
- Back-seating service valves
- High pressure switch
- Loss of charge switch
- Internal pressure relief valve
- Long-line accessory connections
- Suction Line Accumulator
- Vapor fog eliminator
- Ideal Defrost
Controls and Diagnostics - Second generation Infinity control
- Utility Interface Connection
- Up to 23 point diagnostic capability
Applications - Long-line – up to 250 ft. total equivalent length, see Long Line Guide for more information
- Low ambient (down to 0oF)
The Carrier Infinity 19 Series Two-Stage Heat Pump, with Puron refrigerant, Model 25HNA9, is available in 2-5 ton nominal sized units.
Standard Features
Energy Efficiency
- 15.5-19 SEER/11.5-14 EER/9.0 HSPF
New Aesthetic Design
- WeatherArmor UltraTM
– Baked on powder paint
– Steel louver coil guard
– Color matched cabinet screws
Extra Quiet Operation
- Silencer System IITM for sound as low as 72 dBA
– Quiet mount split post compressor grommets
– External silencer muffler
– Exclusive Silencer Top design
– Variable speed outdoor condenser fan motor
– Forward-swept condenser fan blade
– Compressor blanket
- Quiet Shift Defrost
Reliability, Quality and Toughness - Two-Stage scroll compressor
- Field-installed 16 cu. in. filter drier
- Back-seating service valves
- High pressure switch
- Loss of charge switch
- Internal pressure relief valve
- Long-line accessory connections
- Suction line accumulator
- Vapor fog eliminator
- Ideal Defrost
Controls and Diagnostics - Second generation InfinityTM control (Infinity Control MUST be used, no substitutes)
- Utility Interface Connections
- Up to 18 point diagnostic capability
Applications - Long-line – up to 250 ft. total equivalent length; see Long Line Guide for more information
- Low ambient (down to 0oF)